LIQUI-TRANS
PISTON PUMP [Click
to download PDF version]
The Liqui-Trans is capable
of transferring liquid manure very long distances with
low power requirements. The hydraulic power unit is available
in 5HP or 7.5HP models, which makes the Liqui-Trans an
excellent choice for use with single phase electricity
or anywhere that power availability may be limited.
There are two models of
Liqui-Trans pump available: Standard Duty is equipped
with a 3” diameter hydraulic cylinder and the Heavy
Duty, which is equipped with a 4” hydraulic cylinder.
Both models use a heavy gauge 20” diameter stainless
steel pumping cylinder and urethane-edged flapper doors.
Liqui-Trans pumps may be
mounted in a dry pit beside a reception pit with a suction
tube through the wall, or at floor level with a suction
downspout extending down into the reception pit. Depending
on the distance to the storage, the output is either 6”
or 8” diameter PVC pipe. This small diameter pipe
makes installation very economical.
Liqui-Trans pumps are intended
for use only in very liquid manure (maximum 10% solids)
with no long bedding. Manure in the reception pit may
be preconditioned to meet these requirements by adding
waste water and/or by homogenizing if required. The Jamesway
Electric Prop Agitator is commonly used with the Liqui-Trans
to precondition the manure.
Sand bedding is not recommended
with the Liqui-Trans system. The high water content required
in the manure will cause sand to settle in the transfer
pipe and rapidly block the pipe. The exception is when
the Liqui-Trans is used to lift material into a separator
system. A Jamesway representative will review your plan
and recommend a self-cleaning pipe configuration for these
systems.
Air Risers may be installed
along the length of the pipe. This kit includes a 6”
diameter pipe that is attached in a Y-joint to the manure
pipe and runs vertically to end above ground level. Compressed
air may then be used to rapidly push manure forward and
scour the pipe clean. Air risers are recommended with
on any system with a long pipe to allow easy access in
case of line plugging.
Please contact
Jamesway for review and recommendations for systems exceeding
1000 feet of pipe, or systems with extreme vertical lift.
[Back